Preweigh / Dispense Equipment: How It Works
|
Pre-Weigh
- A container is manually or automatically placed into the feed position under the tilt/reject funnel.
- The system meters the material into the weigh/dump pan. The pan is suspended from FillPro's force restoration type weigh sensors. The pre-weighed charge is directed into the funnel.
- Any out-of-tolerance charges are diverted to a reject container, so that only in-tolerance charges are delivered to the container.
- The weight sensor is tared and the value compared for a tare validity test. This test assures complete delivery of the powder out of the dump pan.
- The FillPro 7000 Controller monitors the system operation, stores the fill data, plots histograms and analyzes the statistical results.
- The system provides a digital display of the exact fill weight and stores data for the net-weight of each fill. Fill data can be exported to a printer or other device.
|
|
|
 |
 |